44 REFERENCE & INSTALLATION MANUAL
User Access Code with the Master Feature enabled can also
program the User Options using a different programming method .
To program the User Access Codes, refer the users to appropriate
User Manual: LCD Keypad User’s Manual, LED Keypads User’s
Manual, or Access Control User’s Manual.
14.5.1 Master Feature
SECTIONS [802] TO [896]: OPTIONS [1] AND [2]
[1] [2] Option
Off Off Master Feature Disabled
Off On Master Feature Disabled
On Off Users can create or modify User Access Codes
that have the same partition assignment.
On On Users can create or modify User Access Codes
with the same partition assignment and program
the User Options and Partition Assignment
(assigns only partitions the Master Feature Code
has access to).
14.5.2 Duress
SECTIONS [802] TO [896]: OPTION [3]
When a user is forced to arm or disarm their system, entering a
Duress enabled User Access Code (option [3] On) will arm or
disarm the system and, if programmed, will immediately transmit a
silent alarm to the Central Station.
14.5.3 Bypass Programming
SECTIONS [802] TO [896]: OPTION [4]
The User Access Code with option [4] enabled can program
bypass entries as described in section 16.2.
14.5.4 Arm Only
SECTIONS [802] TO [896]: OPTION [5]
The User Access Code with option [5] enabled can arm assigned
partitions, but cannot disarm any partitions. The type of arming is
determined by the other User Options selected. Please note that
with the Arm Only option, the user who just armed the system can
cancel arming by re-entering the same User Access Code during
the Exit Delay.
14.5.5 Stay & Instant Arming
SECTIONS [802] TO [896]: OPTION [6]
The User Access Code with option [6] enabled, can Stay Arm or
Instant Arm (see section 16.1) assigned partitions.
14.5.6 Force Arming
SECTIONS [802] TO [896]: OPTION [7]
The User Access Code with option [7] enabled will be able to Force
Arm assigned partitions (see section 16.1).
14.5.7 User Menu Access Conditions
SECTIONS [802] TO [896]: OPTION [8]
This feature will govern which partitions users have access to when
entering their access codes. With option [8] on, the control panel
will grant access to all partitions assigned to the User Access
Code. With option [8] off, the control panel will only grant access to
partitions that have been assigned to both the User Access Code
and the keypad.
14.6 USER PARTITION ASSIGNMENT
SECTIONS [802] TO [896]: OPTIONS [1] TO [4]
Each of the 95 User Access Codes can be assigned to one or more
partitions. A user can only arm, disarm and view status of the
partitions assigned to their User Access Codes. Select one or more
of the partitions for each User Access Code as shown in Figure 14-
1 on page 43. The System Master Code or a user with the Master
Feature enabled can also program the User Partition Assignment
using a different method of programming (see section 16.4). For
the Access Control User Code Options, refer to the Programming
Guide under “Programming Access Codes” or to the Access
Control User’s Manual.
14.7 ACCESS CONTROL
SECTIONS [801] TO [896]
For details concerning the Access Control feature available
through the Digiplex system, please refer to the Access Control
Installer’s Guide & Reference Manual.
14.8 MULTIPLE ACTION FEATURE
SECTION [504]: OPTION [1]
By enabling option [1] in section [504], users will remain in the
User Menu after entering their access code. This allows users to
perform more than one action without having to re-enter their
access code. With option [1] off in section [504], the control panel
will exit the User Menu after every action.

Table of Contents