46 REFERENCE & INSTALLATION MANUAL
16 USER FEATURES
16.1 ARMING AND DISARMING FEATURES
Partitions can be armed using various arming methods:
16.1.1 Regular Arming
This method is used for the everyday arming of the system. All
zones within the partition must be closed to arm the system. The
system can also be Regular Armed by using a One-touch Feature
(see section 7.8) or a keyswitch (see section 6.4.5). All users are
able to Regular Arm the partition(s) assigned to their User Access
Codes.
To Regular Arm, users:
1) Enter their [ACCESS CODE]
2) Press the [ARM] key. If the users have access to more than
one partition, they can press the key corresponding to the
desired partition or press [0] to arm all their assigned
partitions.
16.1.2 Stay Arming
Stay Arming will partially arm the partition to permit the user to
remain in the protected area. The programmed Stay Zones (see
section 5.4.3) will not arm when Stay Arming a partition. For
example, the doors and windows can be armed without arming the
motion detectors. The system can also be Stay Armed by using a
One-touch Feature (see section 7.8) or a keyswitch (see section
6.4.2). Only User Access Codes with the Stay and Instant Arm
option enabled can Stay Arm a partition.
To Stay Arm, users:
1) Enter their [ACCESS CODE]
2) Press the [STAY] key. If the users have access to more than
one partition, they can press the key corresponding to the
desired partition or press [0] to arm all their assigned
partitions.
16.1.3 Stay Arming with Delay
Stay Arming with Delay functions like Stay Arming except armed
zones can be programmed with an Entry Delay Timer (see section
5.2.9). If these zones are accidently triggered, the timer will start to
allow the user time to disarm the partition(s).
16.1.4 Instant Arming
This feature is similar to Stay Arming. Instant Arming will partially
arm the partition to permit the user to remain in the protected area,
but all zones, including the entry/exit point, are changed to instant
alarm zones. Therefore, if any armed zone is breached, the alarm
will instantly be triggered. The system can also be Instant Armed
by using a One-touch Feature (see section 7.8) or a keyswitch (see
section 6.4.4). Only User Access Codes with the Stay and Instant
Arm option enabled can Instant Arm a partition.
To Instant Arm, users:
1) Enter their [ACCESS CODE]
2) Press the [5] key. If the users have access to more than one
partition, they can press the key corresponding to the desired
partition or press [0] to arm all their assigned partitions.
16.1.5 Instant Arming with Delay
Instant Arming with Delay functions like Instant Arming except
armed zones can be programmed with an Entry Delay Timer (see
section 5.2.9). If these zones are accidently triggered, the timer will
start to allow the user enough time to disarm the partition(s).
16.1.6 Force Arming
Force Arming allows the user to arm a partition when Force zones
are open (see section 5.4.4). Once the open zone in an armed
partition is closed, however, the system will then arm it as well.
This feature is commonly used when a motion detector is
protecting an area that is occupied by a keypad. For example,
during Force arming the motion detector will remain unarmed until
the user exits the area that it protects. The system will then arm the
motion detector. The system can also be Force Armed by using a
One-touch Feature (see section 7.8) or a keyswitch (see section
6.4.3). Only User Access Codes with the Force Arm option enabled
can Force Arm a partition.
To Force Arm, users:
1) Enter their [ACCESS CODE]
2) Press the [FORCE] key. If the users have access to more than
one partition, they can press the key corresponding to the
desired partition or press [0] to arm all their assigned
partitions.
16.1.7 Disarming
Users can only disarm the partitions assigned to their User Access
Codes. User Access Codes with the Arm Only option (see section
14.5.4) enabled cannot disarm.
To disarm, users:
1) Enter through a designated entry. The Entry Delay Timer will
begin.
2) Enter their [ACCESS CODE]
3) Press the [DISARM] key
16.2 BYPASS PROGRAMMING
Bypass Programming allows users to program the alarm system to
ignore specified zones the next time the system is armed. For a
user to bypass a zone, the zone must have the Bypass option
enabled, the User Access Code must have the Bypass option
enabled, and the zone must be within the User Access Code’s
partition assignment.
To Bypass, users:
1) Enter their [ACCESS CODE]
2) Press the [BYP] key
3) Enter the zones’ 2-digit number
4) Press [ENTER] key to exit
Users can also activate Bypass Recall. Bypass Recall reinstates all
the zones that were bypassed the last time the partition(s)
assigned to the User Access Code were armed.

Table of Contents