9.2 Ethernet hardware configuration
The Ethernet controller is hardware selectable with preprogrammed values from the EEPROM. This is the
normal way to start with all operating systems and NOS.
A. Select the configuration
Selected using the IOS0 - IOS2 jumper.
Refer to the table in the previous chapter.
! RESTART THE PC SYSTEM TO INITIALIZE THE NEW CONFIGURATION !
B. Generate the corresponding NET.CFG file
The NET.CFG file can be altered or created using a normal ASCII editor or with the tools from Digital-Logic.
This step must be taken at the beginning or after selecting a new configuration.
BCONF Create the correct NET.CFG files
C. Starting the Network driver on the workstation: for NW3.11
The following drivers and files are available on the tool disk.
Start the following files in this order (include in the Autoexec.bat file)
LSL low level driver
SMC90000 SMC Driver for Novell V3.11
IPXODI IPX- ODI Driver
NETX Novell Network Shell
Now you can login with your password.
D. Starting the Network driver on the workstation: for Novell Lite
On the tool disk the following drivers and files are available.
Start the following files in this order (include in the Autoexec.bat file)
LSL low level driver
SMC90000 SMC Driver for Novell V3.11
IPXODI IPX-ODI Driver
CLIENT Lite V1.1 Workstation Shell
Now you can login with your password.