4.4 Max. number of units to be connected
Thefollowingtablesshowsthemaximumnumberof
units, which can be connected to a CU 5905 Central
Unit or to an EX 6010 Extension Unit or a PS 6000
.
PowerSupply
In the tables the ‘Feeding Cable’ is defined as the
cable betweenthe CU 5905 (orEX 6010 / PS6000)
andthefirstDC5980Pandthe‘InterconnectingCable
isdefinedasthecableconnectingtwoDC5980P.
4.4.1 CU 5905 – DC 5980P, one chain
The following table showsthemaximumnumberof
units, which can be connected to a CU 5905 Central
Unitwhenusingonlyone
ofthetwo‘Chain’outputs.
Thetablealsoshowsthenumberofunits,whichcan
be connected to each ‘Chain’ output on an EX 6010
ExtensionUnit or to the‘Chain’ outputof aPS 6000
PowerSupply.
Lengthof
FeedingCable

Lengthofinter
connecting
Cable
Total
cable
length
Max.number
ofDC5980P
usingone
outputonly
10m 1m 63m 54
30m 1m 77m 48
50m 1m 91m 42
100m 1m 128m 29
10m 2m 104m 48
30m 2m 114m 43
50m 2m 122m 37
100m 2m 140m 27
Figure 4.4-A Number of units connected using only one chain
outpu on CU 5905
4.4.2 CU 5905 – DC 5980P, two chains
The following table showsthemaximumnumberof
units,whichcanbeconnectedtoboth‘Chainoutputs
simultaneously on a CU 5905 Central Unit in total
usingonlythesuppliedCU5900PowerSupply.
Ifonlyone‘Chain
isusedtheinformationinthetable
abovemustbeused.
Lengthof
FeedingCable

Lengthofinter
connecting
cable,
Total
cable
length
Max.number
ofDC5980P
Usingboth
output
10m 1m 2x39m 2x30
30m 1m 2x58m 2x29
50m 1m 2x76m 2x27
100m 1m 2x122m 2x23
10m 2m 2x66m 2x29
30m 2m 2x84m 2x28
50m 2m 2x100m 2x26
100m 2m 2x142m 2x22
Figure 4.4-B Number of units connected using both chains
4.4.3 CU 5905 – DC 5980P – JB 6104,
one chain
This configuration shows two DC 5980P Conference
Units each connected to an output on a JB 6104
JunctionBoxwith3mcablesbetweeneachJB6104.
Generalnote:MaximumcablelengthfromaJB6104
toaDC5980Pis5mandmaximumoneDC5980Pis
allowedoneachoutputofaJB6104.
Lengthof
Feeding
Cable
Lengthof
cablebetween
eachJB6104
Total
cable
length
Number
ofJB
6104
Max.
number
ofDC
5980P
10m 3 m 76m 23 46
30m 3 m 87m 20 40
50m 3 m 92m 15 30
100m 3m 133m 12 24
Figure 4.4-C Number of units connected using JB 6104
Junction Box, using on chain on CU 5905
4.4.4 CU 5905 – DC 5980P – JB 6104,
two chains
This configuration shows two DC 5980P Conference
Units each connected to an output on a JB 6104
JunctionBoxwith3mcablesbetweeneachJB6104.