6400-065-C-1-09
10
With the hinge mounted on
the corner of the pilaster,
the entrapment area is
eliminated and protection is
not required for this area.
Swing Gate Requirements
The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate
access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that
persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
(ref. UL325 56.8.4.b)
If space is greater than 4 inches,
entrapment protection in this area
is required. ASTM F2200 7.1.1.1
and 7.1.1.2
If space is less than 16 inches,
entrapment protection in this area
is required. ASTM F2200 7.1.1.1
and 7.1.1.2
A
A
Not Allowed OK
A
B
Closed Gate
Closed Gates
Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches. ASTM F2200 4.3
Closed Gate
Opened Gate
Opened Gate
B