Maintenance Section
138
Control Panel - Clean, Inspect
Park the lift truck level, with the forks lowered,
parking brake engaged, directional control lever in
NEUTRAL, and the key switch to OFF.
1. Open the hood.
[OUTSIDE BATTERY CONNECTOR]
[INSIDE BATTERY CONNECTOR]
2. Disconnect the battery.
WARNING
Battery voltage and high amperage are present.
The power modules must be discharged before
any contact with the control panel is made.
Personal injury could result if it has not been
discharged properly.
3. Discharge the head capacitor. See “power
modules” in “When Required” section of this
manual.
WARNING
Pressurized air can cause personal injury.
When using pressurized air for cleaning, wear a
protective face shield, protective clothing and
protective shoes.
The maximum air pressure must be below 205
kPa (30 psi) for cleaning purposes.
4. Clean the control panel with 205 kPa (30 psi)
maximum air pressure, until dust is removed
from the control panel.
[Traction, Pump Controller-80V]