16 Dräger PSS
®
Merlin
®
In Use
5.3.2 Time to Whistle
Repeatedly press and release the information button until the status display shows
TTW BG (Time to Whistle of the electronic monitoring system).
All the active channel screens change to show the actual Time to Whistle status for each
of the logged-on electronic monitoring system. After 10 seconds, all the active channel
screens will default to Time of Whistle.
5.3.3 Pressure
Repeatedly press and release the information button until the status display shows
BAR (pressure).
All the active channel screens change to show the actual pressure status for each of the
logged-on electronic monitoring system. After 10 seconds, all the active channel screens
will default to Time of Whistle.
5.3.4 Temperature (Bodyguard
®
II and Connect ECU only)
Repeatedly press and release the information button until the status display shows
TEMP °C (temperature of the electronic monitoring system).
All the active channel screens change to show the temperature status for each of the
logged-on electronic monitoring system. After 10 seconds, all the active channel screens
will default to Time of Whistle.
5.3.5 Time elapsed
Repeatedly press and release the information button until the status display shows
TIME EL (actual time elapsed since activation of the electronic monitoring system).
All active channel screens change to show the actual time elapsed for each of the logged-on
electronic monitoring system. After 10 seconds, all the active channel screens will default to
Time of Whistle.
5.3.6 Whistle Warning Activation
An audible and visual warning signal is available on the ECB that will alert the ECO of the imminent activation of the whistle
warning of a logged-on electronic monitoring system.
The ECO is also alerted to the actual activation of the whistle warning of the electronic monitoring system.
Both alarms are recognised by a single double-beep and the associated channel screen continuously flashing.
NOTICE
During the commissioning process it is possible to program the first alarm timing to meet customer requirement. Unless
otherwise requested, this first alarm default is 10 minutes before the activation time of the whistle.
1456