There are 19 formats in the PC4010 for communicating with the monitoring station. The system
must be programmed to use the same communications format as the receiver at the monitoring
station. The default format is (01).
(00) 10 Bps 1400 - Silent Knight, Ademco Slow
(01) 20 Bps 2300 - Sescoa, Franklin, DCI, Vertex
(02) 20 Bps 1400 - Silent Knight Fast
(03) 40 Bps 2300 - Radionics
(04) 40 Bps 1400 - Radionics
(05) 40 Bps 2300 P - Radionics with Parity
(06) 40 Bps 1400 P - Radionics with Parity
(07) 10 Bps 1400 X - Silent Knight, Ademco Slow extended
(08) 20 Bps 2300 X - Sescoa, Franklin, DCI, Vertex extended
(09) 20 Bps 1400 X - Silent Knight, Ademco Fast extended
(10) 40 Bps 2300 X - Radionics Extended
(11) 40 Bps 1400 X - Radionics Extended
(12) 40 Bps 2300 XP - Radionics Extended with Parity
(13) 40 Bps 1400 XP - Radionics Extended with Parity
(14) SIA Fsk Format
(15) Sescoa Super Speed
(16) Sescoa Super Speed ID
(17) DTMF Contact ID
(18) 4/3 DTMF Format - Surgard
(19) Pager 1
(20) Pager 2
(21) Pager 3
Communications Compatibility
All these communication formats are compatible with the Silent Knight SK9000 and Ademco
model 685 receivers with the exception of formats (15), (16), (17) and (18). Formats (15) and (16)
are compatible with the Linear/Sescoa model 3000C receiver.
10, 20 and 40 BPS Formats
10 Bits Per Second is the standard slow format used on Silent Knight and Ademco receivers.
Data = 1900 Hz Kissoff = 1400 Hz Speed = 10 Baud
20 Bits Per Second is the standard fast format used on DCI, Franklin, Sescoa and Vertex
receivers.
Data = 1800 Hz Kissoff = 1400/2300 Hz Speed = 20 Baud
40 Bits Per Second is the standard format used on Radionics receivers.
Data = 1800 Hz Kissoff = 1400/2300 Hz Speed = 40 Baud
These formats will send an account code to identify which customer is sending the alarm, and a
reporting code to identify the type of alarm. Depending on the receiver, the account code must be
either 3 or 4 digits, and the reporting code must be either 1 or 2 digits. If the account code needs
to be only 3 digits, program the ‘System ID Code’ and each partition’s ‘Customer ID Code’ with 3
digits, followed by a ‘0’. If you wish to send a zero in the account code, program it with a HEX A.
For example, if you wish to send 103 as your account code, program the System or Customer ID
code with ‘1A30’. If the reporting code needs to only be 1 digit, program the reporting codes with
one digit followed by a ‘0’. For example, to send a ‘3’, program ‘30’ into the reporting codes. To
send a zero, program HEX A into the reporting code. For example, to send 30, enter 3A.
SYSTEM AREA
COMMUNICATOR
MAIN ITEMS
COMMS FORMAT
(1)