SYSTEM AREA
COMMUNICATOR
MAIN ITEMS
Radionics Format
For conventional 3/1 Radionics format the communications mode should be set to either (10) or
(11), the 40 Bps extended format. The following guidelines have been provided to help in
configuring the PC4010 for Radionics format.
1. The system ID code and customer ID codes must be only 3 digits with a zero making up
the 4th digit (i.e. program 1230 for ID code 123.)
2. The zone alarm reporting codes must all be single digit numerical codes with no extended
2nd round being sent. The zero in the 2nd digit of the reporting code tells the PC4010 not to
send an extended code.
3. All other non-alarm reporting codes must be set up to send an extended 2nd round. The
1st digit of the reporting code is used to identify the event while the 2nd or extended digit is
used to associate the event with a particular item. (i.e. A reporting code of E3 means
restore zone 3 - E for restore and 3 for zone 3.)
4. The following is a list of 1st digit identifiers that should be used with the Radionics format.
Restorals “E” Example “E3” = Restore zone 3
Openings “B” Example “B2” = Opening by User 2
Closings “C” Example “C4” = Closing by User 4
Troubles “F” Example “F5” = Trouble from Source 5
Misc “D” Example “D1” = Partial Closing
Alarm “A” Example “A7” = Alarm Zone 7
SIA 1986 Format
The system ID codes and the customer ID codes must be four decimal digits in length. The
reporting codes must be 2 digits.
Note: Do not program the keypad lockout reporting code or the printer buffer nearly full
reporting code.
The SIA format will transmit a 4 digit account code, a 2 digit identifier code and a 2 digit reporting
code. The 2 digit identifier is preprogrammed by the PC4010. The 2 digit reporting code is
programmed by the installer with any hex number from 01 to FE.
Preprogrammed
Identifiers
2 Wire Smoke Alarm FA
2 Wire Smoke Trouble FS
2 Wire Smoke Alarm Restore FR
2 Wire Smoke Trouble Restore FR
2nd Master Close CL
2nd Master Open OP
4204 AC Trouble Restore AR
4204 Aux Supply Trouble Restore UR
4204 Battery Trouble Restore YR
4204 Battery Trouble Alarm YT
4204 Aux Supply Trouble Alarm UT
4204 AC Trouble Alarm AT
Auto Arm Abort CE
Automatic Arming Closing CA
Cellular Trouble LT
Cellular Trouble Restoral LR
Closing Access Codes 1 to 128 CL
Closing Keyswitch CL
COMBUS Trouble Alarm UT
COMBUS Trouble Restoral UR
Downloading Lead In RB
Downloading Lead Out RS
Duress HA
Ground Fault Restore UR
Ground Fault US
DVAC Trouble YS
DVAC Trouble Restore YK
Hold Up Alarm HA
Preprogrammed
Identifiers
Hold Up Restore HR
Installer’s Lead In LB
Installer’s Lead Out LS
Keypad Lockout DC
Keypad [F] Key Alarm FA
Keypad [A] Key Alarm MA
Keypad [P] Key Alarm PA
Keypad [F] Key Restore FR
Keypad [A] Key Restore MR
Keypad [P] Key Restore PR
Links Test RP
Module Tamper Restoral TR
Module Tamper Alarm TA
Opening After Alarm OR
Opening Access Codes 1 to 128 OP
Opening Keyswitch OP
Opening Automatic OA
Panic Alarm PA
Panic Restoral PR
Partial Closing Code CG
Partition Close CL
Partition Open OP
Periodic Test UL RP
Periodic Test RP
Police Restore BR
Police Alarm BA
Printer Buffer Nearly Full JL
Quick Arm Closing Code CL