18
SYSTEM AREA
COMMUNICATOR
MAIN ITEMS
Technical Restore UR
Waterflow Trouble Restore SR
Waterflow Alarm SA
Waterflow Alarm Restore SR
Waterflow Trouble SS
Automation Fault ET
Automation Restore ER
Zone Alarms 1 to 128 - Fire FA
Zone Alarms 1 to 128 - All others BA
Zone Sensor Fault ET
Zone Low Bat Alarm XT
Zone Sensor Fault ET
Zone Low Bat Restore XR
Zone Troubles 1 to 128 - Fire FT
Zone Fault Restore TR
Zone Tamper 1 to 128 TA
Zone Fault TA
Zone Sensor Fault Restore ER
Zone Restorals 1 to 128 - All others BR
Zone Restorals 1 to 128 - Fire FR
Zone Tamper Restorals TR
RS-232 Trouble VT
RS-232 Restore VR
Sprinkler Zone Trouble ST
Sprinkler Zone Trouble Restore SR
Sprinkler Zone Alarm SA
Sprinkler Zone Restore SR
System TLM Restore Line 2 LR
System TLM Trouble LT
System Bell Trouble Alarm UT
System AC Trouble Alarm AT
System Battery Trouble Alarm YT
System TLM Trouble Line 2 LT
System FTC Restoral UR
System TLM Restoral LR
System AUX Supply Trouble Alarm UT
System Test RX
System AC Trouble Restoral AR
System Aux Supply Trouble Restoral UR
System Battery Trouble Restoral YR
System Bell Trouble Restoral UR
Technical Alarm UA
Sescoa Super speed and Sescoa Super Speed ID
The system ID code and customer ID codes must be four decimal digits in length and in the range
of 0001 to 3374.
The reporting codes must be 2 digits in length and programmed as follows. All zero’s must be
replaced with ‘A’s. For example, to send 20, the PC4010 must be programmed with a 2A. (To
disable a reporting code, leave as FF.)
Notes: Do not program the Downloading Lead In reporting code, the Downloading Lead Out
reporting code, the Installer’s Lead In reporting code, the Installer’s Lead Out Reporting Code,
the RS-232 Trouble Alarm Rep Code or the RS-232 Trouble Restoral Rep Code.
The keyswitch zones will be identified as the zone number plus 128. For example, if the
closing user zone and the closing keyswitch zone numbers are both 002, the closing
keyswitch zone will then be identified as 130 (zone number 2 + 128 = 130).
Program different reporting codes for zone tamper and zone alarm for identifying a zone
tamper from a zone alarm.
Code
2 Wire Smoke Alarm Trouble A1 to 9A
2 Wire Smoke Alarm Restore A1 to 9A
2 Wire Smoke Alarm A1 to 9A
2 Wire Smoke Alarm Trouble Restore A1 to 9A
2nd Master Close CA
2nd Master Open BA
4204 Battery Trouble Restore E1
4204 Aux Supply Trouble Restore A1 to 9A
4204 AC Trouble Alarm E1
4204 Battery Trouble Alarm E1
4204 Aux Supply Trouble Alarm A1 to 9A
4204 AC Trouble Restore E1
Auto Arm Abort C1
Automatic Closing CA
Automatic Opening BA
Buffer Near Full A1 to 9A
Cellular Trouble Restoral EE
Cellular Trouble EE
Closing Reporting Codes 1 to 128 CA
COMBUS Trouble Restore A1 to 9A
COMBUS Trouble Alarm A1 to 9A
Code
DVAC Trouble EE
DVAC Trouble Restore EE
Duress D1
Ground Fault A1 to 9A
Hold Up Restore A1 to 9A
Hold Up Alarm A1 to 9A
Keypad [P] key Restoral A1 to 9A
Keypad [F] key Alarm A1 to 9A
Keypad Lockout Code A1 to 9A
Keypad [F] key Restoral A1 to 9A
Keypad [A] key Restoral A1 to 9A
Keypad [A] key Alarm A1 to 9A
Keypad [P] key Alarm A1 to 9A
Keyswitch Opening BA
Keyswitch Closing CA
Links Test 1C
Module Tamper Restorals A1 to 9A
Module Tamper Alarms A1 to 9A
Opening After Alarm Code BA
Opening Reporting Code 1 to 128 BA
Panic Alarm A1 to 9A