Service Manual for Flexible Batch Broiler Units
16
9. Slide new compression nut, tting and sleeve
onto Temperature Probe sheath.
10. Insert Temperature Probe into tube fully and
tighten compression nut.
Cook Chamber
Temperature Probe
Connection
Cook Chamber Temperature Probe
Connection
Cook Chamber
Temperature Probe
Compression
Nut
Cook Chamber Temperature Probe Mounting
COOK CHAMBER TEMPERATURE PROBE
The Cook Chamber Temperature Probe connects
to the bottom of the Control Board and is located
on the back of the broiler.
WARNING
DISCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDURES.
1. Remove the Electrical Access Panel. Refer
to the COVERS and PANELS section of the
manual.
2. Remove the Rear Panel. Refer to the COVERS
and PANELS section of the manual.
3. Remove the two screws that secure the Control
Board Bezel.
4. Disconnect the Cook Chamber Temperature
Probe connector at the bottom of the Control
Board.
5. Remove the Cook Chamber Temperature
Probe from the broiler by loosening the
compression nut.
6. Slide the Cook Chamber Temperature Probe
out of the broiler.
7. Route new Temperature Probe through Control
Shroud and through panel.
8. Make connection at the Control Board and
replace Control Board Bezel.