EasyManua.ls Logo

Duke FBB-EO-208 - Fuse Replacement

Duke FBB-EO-208
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual for Flexible Batch Broiler Units
22
FUSE REPLACEMENT
1. Check the fuses on the Fuse Panel. A lit
Indicator lamp means a blown fuse.
2. Unplug the broiler.
3. Open the fuse holder(s) to remove any blown
fuse(s).
4. Replace any blown fuse(s) with correctly rated
replacement fuse(s).
5. Close the fuse holder. Plug in the broiler and
check the indicator lamps. They should not be
lit with a good fuse in place.
6. Reinstall the Fuse Access Panel
7. Broiler will go into preheat mode indicating
proper operation.
NOTE: This unit also comes equipped with
a safety interlock system located on the rear
access panel for additional user safety. The
rear access panel must be mounted correctly or
power will not be supplied to heating elements.

Table of Contents