Service Manual for Flexible Batch Broiler Units
PREVENTIVE MAINTENANCE
SEMIANNUAL
It is recommended to perform preventative
maintenance on the Broiler every 6 months. Over
time, dust and debris will accumulate, electrical
connections will loosen, and the following procedures
and inspections should be made to extend the life
of the components within the Broiler.
1. Vacuum dust and dirt from the cooling fan and
heat sink ns.
2. Perform a visual inspection of the Broiler, noting
and repairing any electrical connection which
appears damaged.
3. Check tightness of all electrical connections
throughout the Broiler. Pay particularly close
attention to all Element, Solid State Relay, and
Terminal Block connections as these will be
more affected over time.
4. Check tightness of electrical connections within
Plug and at receptacle