9000X AF Drives User Manual
5-20 For more information visit: www.eaton.com
MN04001004E
June 2009
Multimonitor (V7.17)
This parameter allows the viewing and selection (if allowed by System menu item, P5.5.4) of
three simultaneously monitored items from the Monitored Menu Items shown in Table 5-12.
Use the right arrow key to select the item to be modified and then the up or down arrow keys
to select the new item. Press the ENTER key to accept the change.
Operate Menu (M8)
The Operate Menu provides a easy to use method of viewing key numerical Monitoring
Menu items. Some applications also support the setting of reference values in this menu. The
items displayed vary by application. Table 5-13 is an example for the Standard application.
Table 5-13: Operate Menu Items — Standard Application Example
The menu is navigated by using the left and right arrow buttons. If a reference level is
available for setting, the up and down arrow buttons adjust the value. To exit the Operate
Menu to access the other menus, depress the ENTER button for 2 seconds. While in the other
menus, if there is no keypad activity, the display will return to the Operate Menu after 30
seconds. Figure 5-12 illustrates the Operate Menu button function.
Code Signal Name Unit Description
O.1 Output Frequency Hz Output frequency
O.2 FreqReference Hz Frequency reference
O.3 Motor Speed rpm Calculated motor speed
O.4 Motor Current A Measured motor current
O.5 Motor Torque % Calculated torque based on nominal motor torque
O.6 Motor Power % Calculated power based on nominal motor power
O.7 Motor Voltage V Calculated motor voltage
O.8 DC-Bus Voltage V Measured DC-bus voltage
O.9 Unit Temperature °C Heatsink temperature
O.10 MotorTemperature % Calculated motor temperature based on the motor
nameplate information and the calculated motor load
R1 Keypad Reference Hz Keypad frequency reference setting