6 Parameters
6.1 Operating unit
104 DC1 Frequency Inverter 10/12 MN04020003Z-EN www.eaton.com
6.1 Operating unit
The following figure shows the elements of the DC1 frequency inverter inte-
grated operating unit.
Figure 56: Operating unit view
Table 13: Operating unit elements
Operating unit element
Explanation
Six-digit 7-segment LED display
Motor starter with pre-selected operating direction if parameter P-12 = 1
(FWD) or P-12 = 2 (FWD / REV).
Note:
Enable with +24 V on control signal terminal 2 (DI1)
P-12 = 2: The first time it is pressed (commissioning, parameter reset), a
clockwise rotating field (FWD) will always be activated. Only after it is
pressed for a second time will the direction of the rotating field change
to a counterclockwise rotating field (REV).
(This setting will be retained even after the supply voltage is switched
off.)
Stops the running motor if P-12 = 1 or P-12 = 2
Reset – Resetting after an error message
Activate parameter input (editing mode)
Activate parameter value, change (display value flashes)
Confirm (store) and activate configured value
Increment numeric value or parameter number
Increase output frequency / motor speed if P-12 = 1 or P-12 = 2
Decrement numeric value or parameter number
Reduce output frequency / motor speed if P-12 = 1 or P-12 = 2