6 Technical Data
6.2 Specific rated operational data
DA1 Variable Frequency Drives 11/16 MN04020005Z-EN www.eaton.com 155
DA1-35… series
Physical quantity Symbol Unit 017 022 022 028 034 043
Rated operational current I
e
A 17 22 22 28 34 43
Overload current for 60 s every 600 s i
l
A 25.5 33 33 42 51 64.5
Apparent power at rated operation 500 V S kVA 10.4 12.7 12.7 16 19.5 24.4
600 V S kVA 12.5 15.2 15.5 19.3 23.4 29.3
Assigned Instance Motor Power 500 V P kW 11 15 15 18.5 22 30
575 V P HP 15 20 20 25 30 40
Power side (primary side):
Number of phases three-phase
Rated operating voltage U
LN
V 500V -10% - 600V +10%, 50/60Hz
Input current (phase current) I
LN
A 21 26 26 33 40 49
Minimum braking resistance R
B
Ω 40 40 22 22 22 22
Switching frequency (pulse frequency)
Default settings f
PWM
kHz 8 8 8 8 8 8
Setting range f
PWM
kHz 24 24 24 24 24 24
Maximum leakage current to earth (PE), without motor I
PE
mA – – – – – –
Efficiency η 0.97 0.97 0.97 0.97 0.97 0.97
Heat dissipation at I
e
P
V
W 330 450 450 555 660 850
Frame size FS3 FS3 FS4 FS4 FS4 FS4