24
Discharge Cut-off SOC(%): Set this according to the battery requirements. Range is 0-90
%
On Grid EOD Voltage(V): The inverter will stop discharging the battery at this Voltage and
will use AC to power loads.
On Grid EOD SOC(%): The inverter will stop discharging the battery at this SOC and will
use AC to power loads.
6.5 OTHER SETTING
Batt Volt Sample Disable: Set to Internal, External or Both Available.
Fan 1 Max Speed(%): This sets cooling fan 1 max. speed. Range is 50-100%.
Fan 2 Max Speed(%): This sets cooling fan 2 max. speed. Range is 50-100%.
6.6 RESET
All to Default: This resets all settings to factory default values.
NOTE: Be sure to keep track of your settings and what changes need to be made before powering
the system back on!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 LuxPowerTek 6000XP and is the answer not in the manual?

EG4 LuxPowerTek 6000XP Specifications

General IconGeneral
CategoryInverter
Rated Power6000W
Max DC Input Power7800W
Number of MPPT Trackers2
Battery Voltage48V
Max Charge/Discharge Current120A
Protection DegreeIP65
Frequency50/60Hz
ModelLuxPowerTek 6000XP
CommunicationRS485
Operating Temperature Range-25°C to 60°C
Protection FeaturesOver Voltage Protection, Over Temperature Protection
CoolingFan