14. INVERTER MAINTENANCE
Electrical equipment must be properly maintained to increase longevity and consistency.
Follow the steps below to help prevent component damage/deterioration.
1. Inspect the inverter every month to confirm nothing covers the inverters heatsink. If there is,
shut down the inverter and clear the heat sink to restore proper cooling.
2. Inspect the inverter every 3 months to verify the operating parameters are normal, and there is
no abnormal heating or noise from all components in the system.
3. Inspect the inverter every 6 months to check for any damaged cables, accessories, or terminals,
and inspect the inverter itself.
15. TECHNICAL SPECIFICATIONS
NOMINAL AC VOLTAGE 120-240VAC
MAX. CONTINUOUS AC CURRENT
MAX. CONTINUOUS OUTPUT CURRENT @
240V
25A
NOMINAL POWER OUTPUT
6000W
REACTIVE POWER ADJUST RANGE
(-0.8) – (+0.8) leading adjustable
BACKUP/UPS AC OUTPUT DATA
RATED OUTPUT CURRENT @ 240V
12kW for ≈3.5 seconds | 11kW for ≈5 seconds
<15ms @ Single / <30ms @ Parallel
MAX. USABLE INPUT CURRENT
MAX. SHORT CIRCUIT INPUT CURRENT
MPP OPERATING VOLTAGE RANGE