Alarm
Description
Possible fault
Machine status/action
Reset
EF1
Drain filter clogged
(drain phase too long)
Drain filter clogged/dirty;
Drain hose blocked/kinked/too high.
Warning displayed at the end of cycle
START/RESET
EF2
Overdosing of detergent
(too much foam during drain
phases)
Excessive detergent dosing; Drain hose kinked/blocked;
Drain filter clogged/dirty.
Warning displayed after 5 attempts
or by the specific LED
RESET
EF3
Aqua control system intervention
Water leaks onto base frame; Aqua control system faulty;
Drain pump coil overheating/broken.
Appliance drains
ON/OFF RESET
EF4
Water fill pressure too low, no
signal from flow meter and
electronically controlled valve
is open
Tap closed, water fill pressure too low.
----------------
RESET
EF5
Unbalanced load
Final spin phases skipped.
----------------
START/RESET
EF6
Reset
If it continues, replace the main board.
No action to be taken
----------------
EH1
Power supply frequency of
appliance outside the limits
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal
frequency conditions
ON/OFF
EH2
Supply voltage too high
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal
voltage conditions
ON/OFF
EH3
Supply voltage too low
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal
voltage conditions
ON/OFF

Table of Contents