2-1
SECTION 2. COMPONENTS
REPLACING THE COMPRESSOR
1. Disconnect the unit from the power
source.
2. Locate defective compressor and
evacuate the sealed system. (See
Sweep Charging and Refrigerant
Recovery.)
3. Clean and cut the refrigerant lines as
close as possible to the compressor
stubs, leaving enough length to install
the replacement compressor.
Cut
Here
The holding charge is your assurance that
the compressor is dry and ready to install.
If you receive a replacement compressor
that shows no evidence of holding charge
when you center the lines or remove the
plugs, return it.
NOTE: A new drier must be installed each
time any component of the system is
opened or replaced.
COMPRESSOR REPLACEMENT
The following general information explains
how to successfully replace compressors
for any model covered in this manual.
All replacement compressors are charged
with the correct amount of oil and a holding
charge of dry nitrogen.
Cut
Here
Cut
Here