Rosemount Model 1195/ProPlate/Mass ProPlate
6-14
NOTE
This manual does not contain instructions regarding the Calibrated Mass
ProPlate Primary Element. For information concerning this option, call
Rosemount Customer Central at 1-800-999-9307.
5. Define Primary Element Information.
a. Enter the Primary Element minimum diameter. The Primary
Element minimum is the bore size. See Figure 6-6.
b. Enter Primary Element Material.
c. Enter Meter Tube Diameter (pipe ID) and units at
reference temperature. This is the B.D. in Figure 6-6.
d. Enter Meter Tube Material.
NOTE
To be in compliance with appropriate national or international standards,
beta ratios and differential producer diameters should be within the limits
as listed in the standards.The EA software will alert the operator if a
primary element value exceeds these limits. However, the EA will not stop
the operator from proceeding with a flow configuration because of this type
of exception.
6. Enter Operating Conditions.
Figure 6-6.
Flow Setup Screen
(Gas Configuration).