EasyManua.ls Logo

Endress+Hauser Cerabar M PMC41 - Page 35

Endress+Hauser Cerabar M PMC41
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cerabar M
Endress+Hauser 35
Hygienic connections, flush-mounted diaphragm
Many process connections with an EPDM or HNBR seal are approved for the PMC45 in accordance with the
guidelines of the 3A Sanitary Standard. To ensure that the 3A approval applies to the PMC45 version, a
3A-approved process connection together with an EPDM or HNBR seal must be selected when ordering.
For ordering information on EPDM or HNBR seals, see Page 69 "Ordering information PMC45", feature 80
"Seal".
P01-PMC45xxx-06-09-xx-xx-004
Process connections PMC45, hygienic connections, material AISI 316L
Surface roughness of the surfaces in contact with the medium R
a
0.8 μm as standard. Lower surface roughness on
request.
Version EG: SMS 1 1/2" PN 25, EHEDG, 3A with HNBR or EPDM seal
Version EL: SMS 2" PN 25, EHEDG, 3A with HNBR or EPDM seal
Version HL: APV-Inline DN 50 PN 40, EHEDG, 3A with HNBR or EPDM seal
Version LB: Varivent type F for pipes DN 25 – DN 32 PN 40, EHEDG, 3A with HNBR or EPDM seal
Version LL: Varivent type N for pipes DN 40 – DN 162 PN 40, EHEDG, 3A with HNBR or EPDM seal
21
10
ø26
ø48
Rd 65 x 1/6
153.5 (173.5)
22
11
ø26
ø61
Rd 78 x 1/6
153.5 (173.5)
163.5 (178.5)
163.5 (178.5)
ø55
ø26
Rd 60 x 1/6 "
153.5 (173.5)
25
163.5 (178.5)
ø65
ø26
153.5 (173.5)
26
Rd 70 x 1/6 "
163.5 (178.5)
6xø8.6+2xM8
ø63.5
ø26
ø69
ø82
ø100
12.5
153.5 (173.5)
163.5 (178.5)
ø50
ø26
ø66
153.5 (173.5)
163.5 (178.5)
153.5 (173.5)
163.5 (178.5)
ø68
ø26
ø84
ø65
ø26
ø84
16
4xø11.5
ø105
153.5 (173.5)
163.5 (178.5)
SMS 1½"
SMS 2"
APV-Inline DN 50
8 x 45° (=360°)
Varivent DN 25 DN 32
Varivent DN 40 DN 162
DRD 65 mm
DIN 11851 DN 40
DIN 11851 DN 50

Table of Contents

Other manuals for Endress+Hauser Cerabar M PMC41

Related product manuals