Loading...
The "Expert" menu Micropilot FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/FMR57 FOUNDATION Fieldbus
56 Endress+Hauser
Parameters of the "Linearization" submenu
Task Required parameters Parameter description
Selection of linearization type and unit after
linearization
Linearization type (→  57)
Unit after linearization (→  58)
Free text (→  59)
Display of the linearized level
1)
Level linearized (→  53)
Parametrization of the linearization Linearization type = Linear
Maximum value (→  60)
Linearization type = Horizontal cylinder / Sphere
Maximum value (→  60)
Diameter (→  60)
Linearization type = Pyramid bottom / Conical bottom / Angled
bottom
Maximum value (→  60)
Intermediate height (→  60)
Linearization type = Table
Table mode (→  61)
Table number
1)
(→  62)
Level (→  62)
Customer value (→  63)
Activate table (→  63)
1) Only for operation via operating tool (e.g. FieldCare), not on the local display module