EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow 93T Portable - Page 112

Endress+Hauser Proline Prosonic Flow 93T Portable
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of Device Functions Proline Prosonic Flow 93T Portable
112 Endress+Hauser
SENSOR CONFIGURATION
(6882)
Use this function to select the configuration for the ultrasonic sensors, e.g. the number
of traverses (in the Clamp On version).
!
Note!
This function is not available unless one of the following options was selected in the
function MEASUREMENT (6880):
•CLAMP ON
SOUND VELOCITY LIQUID
INSERTION (is not supported by the measuring device)
Options
NO. TRAVERSE: 1
1)
NO. TRAVERSE: 2
2)
SINGLE PATH
3)
(is not supported by the measuring device)
DUAL PATH
3)
(is not supported by the measuring device)
Factory setting
NO. TRAVERSE: 2
1)
This option is not available unless CLAMP ON or SOUND VELOCITY LIQUID
was selected in the function MEASUREMENT.
2)
This option is not available unless CLAMP ON was selected in the function
MEASUREMENT.
3)
This option is not available unless INSERTION was selected in the function
MEASUREMENT.
!
Note!
The setting "NO. TRAVERSE: 2" is required for sensors with a nominal diameter range
from DN15 to DN 65.
CABLE LENGTH
(6883)
Use this function to select the length of the sensor cable.
Options
LENGTH 5 m/15 feet
LENGTH 10 m/30 feet
Factory setting
LENGTH 5 m/15 feet
POSITION SENSOR
(6884)
Use this function to view the position of both sensors on the rail.
User interface
5-digit number combination
WIRE LENGTH
(6885)
The wire length for assembling the sensors at the correct distance apart appears on the
display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
SENSOR DISTANCE
(6886)
The distance between sensor 1 and sensor 2 as a length measurement appears on the
display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
ARC LENGTH
(6887)
The arc length on the pipe appears on the display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
PATH LENGTH
(6888)
The path length appears on the display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
Functional description
BASIC FUNCTION SENSOR DATA SENSOR PARAMETER

Table of Contents