Description of Device Functions Proline Prosonic Flow 93T Portable
112 Endress+Hauser
SENSOR CONFIGURATION
(6882)
Use this function to select the configuration for the ultrasonic sensors, e.g. the number
of traverses (in the Clamp On version).
!
Note!
This function is not available unless one of the following options was selected in the
function MEASUREMENT (6880):
•CLAMP ON
• SOUND VELOCITY LIQUID
• INSERTION (is not supported by the measuring device)
Options
NO. TRAVERSE: 1
1)
NO. TRAVERSE: 2
2)
SINGLE PATH
3)
(is not supported by the measuring device)
DUAL PATH
3)
(is not supported by the measuring device)
Factory setting
NO. TRAVERSE: 2
•
1)
This option is not available unless CLAMP ON or SOUND VELOCITY LIQUID
was selected in the function MEASUREMENT.
•
2)
This option is not available unless CLAMP ON was selected in the function
MEASUREMENT.
•
3)
This option is not available unless INSERTION was selected in the function
MEASUREMENT.
!
Note!
The setting "NO. TRAVERSE: 2" is required for sensors with a nominal diameter range
from DN15 to DN 65.
CABLE LENGTH
(6883)
Use this function to select the length of the sensor cable.
Options
LENGTH 5 m/15 feet
LENGTH 10 m/30 feet
Factory setting
LENGTH 5 m/15 feet
POSITION SENSOR
(6884)
Use this function to view the position of both sensors on the rail.
User interface
5-digit number combination
WIRE LENGTH
(6885)
The wire length for assembling the sensors at the correct distance apart appears on the
display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
SENSOR DISTANCE
(6886)
The distance between sensor 1 and sensor 2 as a length measurement appears on the
display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
ARC LENGTH
(6887)
The arc length on the pipe appears on the display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
PATH LENGTH
(6888)
The path length appears on the display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
Functional description