Proline Prosonic Flow 93T Portable Technical data
Endress+Hauser 57
10 Technical data
10.1 Quick technical data guide
10.1.1 Application
Measuring the flow rate of liquids in closed piping systems.
Applications in measuring, control and regulation technology for monitoring processes.
10.1.2 Function and system design
Measuring principle The measuring system operates on the principle of transit time difference.
Measuring system The measuring system consists of one transmitter and two sensors.
Transmitter
Prosonic Flow 93T Portable
Sensor
Prosonic Flow P Clamp On version, Nominal diameters DN 15 to 65 (½ to 2½")
Prosonic Flow P Clamp On version, Nominal diameters DN 50 to 4000 (2 to 160")
Prosonic Flow DDU18 (sound velocity measurement),
Nominal diameters DN 50 to 3000 (2 to 120")
Prosonic Flow DDU20 (wall thickness measurement),
for wall thicknesses from 2 to 50 mm (1/12 to 2") for steel pipes
for wall thicknesses from 4 to 15 mm (1/8 to ½") for plastic pipes
(only suitable for use with PTFE and PE pipes to a certain extent)
10.1.3 Input
Measured variable Flow velocity
(transit time difference proportional to flow velocity)
Measuring range Typically v = 0 to 15 (0 to 50 ft/s)
Operable flow range Over 150 : 1
Input signal Current input
Galvanically isolated
Passive: 0/4 to 20 mA, R
i
< 150 , max. 30 V DC
Terminal voltage: min. 2 V DC to max. 30 V DC
Time constant selectable (0.05 to 100 s)
Full scale value adjustable
Temperature coefficient: typ. 0.002 % o.r./°C (o.r. = of reading)
Resolution: 0.82 μA