DISPLAY (continued)
ASSIGN LINE 1
(p. 67)
FLOW RATE
TOTAL VOLUME
BATCH QUANTITY BATCH UPWARDS
BATCH DOWNWARDS BATCH CYCLE
Your setting: ............................................
ASSIGN LINE 2
(p. 67)
OFF
FLOW RATE
TOTAL VOLUME
TOTAL OVERFLOW
BATCH QUANTITY
BATCH UPWARDS
BATCH DOWNWARDS
BATCH CYCLE
Your setting: ............................................
DISPLAY DAMPING
(p. 68)
max. 2-digit number: 0...99 s
Factory setting:
1 s
Your setting: ............................................
DISPLAY
FORMAT
(p. 68)
x.xxxx
5 significant digits
x.xxx 4 significant digits
x.xx 3 significant digits
Your setting: ............................................
LCD CONTRAST
(p. 68)
IIIIIIIIIIII ...........
A change in contrast is immediately seen
on the bar graph
LANGUAGE
(p. 68)
ENGLISH DEUTSCH
FRANCAIS ESPANOL
ITALIANO – NEDERLANDS
DANSK NORSK SVENSKA
SUOMI – BAHASA INDONESIA
JAPANESE (in original alphabet)
Your setting: ............................................
COMMUNICATION
PROTOCOL
(p. 69)
With “HART communication module:
OFF
HART
With “RS 485” communication module:
OFF
RACKBUS RS 485
Communication module: .........................
Your setting: ............................................
BUS ADDRESS
(p. 69)
max. 2-digit number:
0
...15 (HART);
0
...63 (RS 485)
Your setting: ............................................
ASSIGN
AUX. INPUT
(S. 69)
For “Pulsed mode”:
RESET TOTALIZER
BATCHING
For “Level mode”:
DUAL RANGE MODE
POS. ZERO RETURN
Your setting: ............................................
COMMUNICATION (continued)
START PULSE
WIDTH
(S. 71)
max. 3-digit number:
20
...100 ms
Your setting: ............................................
SYSTEM CONFIG.
(p. 71)
Display (only with “RS 485” communication
module)
RS 485 / CURRENT
RS 485 / FREQUENCY
AUX. INPUT / CURRENT
AUX. INPUT / FREQ.
PROCESSING PARAMETERS
LOW FLOW
CUTOFF
(p. 72)
5-digit floating point: e.g. 15.000 dm
3
/min
Factory setting:
dependent
on diameter
Your setting: ............................................
NOISE
SUPPRESS.
(p. 72)
OFF LOW
MEDIUM
HIGH
Your setting: ............................................
EMPTY PIPE
DET.
(p. 73)
Two functions:
Switching on/off “Empty pipe detection”
Start empty or full pipe adjustment
OFF
ON – EMPTY PIPE ADJ. –
FULL PIPE ADJUST
Your setting: ............................................
EPD
RESPONSE TIME
(p. 74)
1s
2 s 5 s 10 s 30 s 60 s
Your setting: ............................................
MEASURING
MODE
(p. 75)
UNIDIRECTIONAL
BIDIRECTIONAL
Your setting: ............................................
FLOW DIRECTION
(p. 75)
FORWARD
1)
REVERSE
2)
1)
Positive flow according to the arrow
on the nameplate
2)
Positive flow in the opposite direction
to the arrow on the nameplate
Your setting: ............................................
FUNCTION ECC
(p. 75)
ON
OFF
Your setting: ............................................
RECOVERY TIME
ECC
(p. 76)
max. 3-digit number: 1...255 s
Factory setting:
5s
Your setting: ............................................
AMPLIFIER MODE
(p. 76)
NORMAL
(automatic control)
MODE 1 (v = 0...>12 m/s)
MODE 2 (v = 0...12 m/s)
MODE 3 (v = 0... 4 m/s)
MODE 4 (v = 0... 1 m/s)
Your setting: ............................................
DELAY
(p. 76)
max. 4-digit number: 10...1000
Factory setting:
10
Your setting: ............................................