MessaPes
05
current info in DIR buffer is not valid data 17 file size greater than limit = 33 Mbytes
06 current info in FAT buffer is not valid data 32-35 and 40*-44 NEC PD 72069 errors
*Please note that error 40 error 040 are separate errors. Error 40 is always a disk controller or disk drive related
problem. Error 040 is always an ESP problem. In the case of error 040 the problem will always be an ESP
problem, in the case of error 40 the problem can be the disk drive controller (located on the digital board) or a
disk drive problem. Replace the disk drive with a known good drive first. If the error still persists, than replace
the digital board.
The following errors could be caused by a bad disk or disk drive:
09 block write attempt failed
13
directory save verify error
11
device id pcb load/save error
14
fat save verify error
12
operating system pcb load/save error
22 possible disk drive index pulse problem
The following errors could be caused a bad external SCSI cable or a SCSI termination problem:
18
scsi command not complete/no disconnect ret
20 scsi last command ignored
2 1
scsi check condition error
The following special message is not an error message:
Not an EPS device. See the SCSI section of this manual
for further explaination.
24
ASR Service Manual

Table of Contents

Other manuals for ENSONIQ ASR-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ENSONIQ ASR-10 and is the answer not in the manual?

ENSONIQ ASR-10 Specifications

General IconGeneral
BrandENSONIQ
ModelASR-10
CategoryRecording Equipment
LanguageEnglish

Related product manuals