Initial Installation
QUALIFIED INSTALLERS ONLY
ReaR vent - coRneR instaLLation
Snorkel
Termination
6” (15.2 cm)
Minimum Wall
Clearance
6” (15.2 cm)
Minimum Wall
Clearance
45° Elbow
(Accounts for 6” of run)
Figure 53: Rear Vent Corner Install Venting - Top View
ATTENTION
When performing an LP Rear Vent Corner Install with 45° Elbow, a DURAVENT 36
SNORKEL MUST BE USED. No other brand venting can be used for LP corner installations.
Rear vent corner installs have the same vent run restrictions as a typical rear vent installations. Refer to Table
7 in the previous section for details.