41
Initial Installation
QUALIFIED INSTALLERS ONLY
gas Line connection
WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to
this appliance.
Natural Gas [NG] Propane [LP]
Main Orifice #37 #53
Max Manifold Pressure 3.6 inch W.C. (0.89 kPa) 10 inch W.C. (2.49 kPa)
Min� Manifold Pressure 1.6 inch W.C. (0.39 kPa) 6.4 inch W.C. (1.59 kPa)
Max Supply Pressure 7 inch W.C. (1.74 kPa) 11 inch W.C. (2.74 kPa)
Min. Supply Pressure 4.5 inch W.C. (1.12 kPa) 10.4 inch W.C. (2.59 kPa)
Max BTU/hr Input 30,000 BTU/hr (8.79 kWh) 25,500 BTU/hr (7.47 kWh)
Min. BTU/hr Input 19,000 BTU/hr (5.57 kWh) 20,600 BTU/hr (6.04 kWh)
Table 9: Pressure and BTU Information
gas Line connection
This stove is equipped with a certified flexible pipe located on the left side of the unit terminating in a 3/8”
female NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in
Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel
Gas Code ANSI Z223.1.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous
operating conditions and was determined independently of any installed system.
The appliance and its shutoff valves must be disconnected from the gas supply piping system during any
pressure testing where the pressure exceeds ½ PSIG (3.45 KPa) or damage will occur to the valve.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½
PSIG (3.45 KPa).
*Note: Always check for gas leaks with a
soap and water solution after completing
the required pressure test.
The pressure taps are located on the bottom left
of the valve as shown in Figure 59.
• Turn the set screw 1 turn counter clockwise to
loosen.
• Place 5/16” (8 mm) I.D. hose over pressure
tap system.
• Check pressures using a manometer.
• When finished, release pressure, remove
hose, and tighten set screw.
Inlet Pressure Tap
Manifold Pressure Tap
HI/LOW Knob
Gas Control Knob
Pilot Adjustment Screw
Figure 59: Fully Labeled Gas Valve