48
ReLocating gas/eLectRicaL
By default, the electrical and gas connections are found
at the back of the unit. There is an option to reroute
the gas and electrical connections through the pedestal
for a more concealed look.
The conversion must be done before pedestal installa-
tion. The conversion can be made while the unit is still
on the pallet - use the pedestal foam packaging as a
cushion to tip the unit back onto for bottom access.
Start by removing the door frame, front skirt, and rear
chassis (refer to their respective sections on page 15
to page 17 for more detailed instructions).
1. Disconnect the IEC outlet plate (see Figure 79).
2. Disconnect the wires attached to the IEC electrical outlet
and remove the outlet from the steel plate. Make note of
how the plug is wired as it will need to be rewired shortly
af ter.
3. Press the IEC outlet into the adapter plate (included in
the manual bag). Refer to Figure 80 for proper geometry
and orientation. Make sure tangs are completely
seated of the plug will not engage fully.
4. Rewire the IEC electrical outlet and position over the hole
shown in Figure 78.
5. Attach the adapter plate through the firebox reusing the
two (2) T20 screws (see Figure 81).
ReLocating eLectRicaL connection
Initial Installation
QUALIFIED INSTALLERS ONLY
Gas
Connection
Electrical
Connection
Figure 78: Gas & Electrical Connection Points
(Bottom View)
Figure 79: Electrical Plug Disconnect
Figure 80: Electrical Adapter Plate
Figure 81: Electrical Plug Connection
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.