QUALIFIED INSTALLERS ONLY
ReLocating gas connection
1. Disconnect the two (2) T20 screws securing the ball valve
plate (see Figure 82).
2. Disconnect the four (4) T20 screws securing the ball
valve.
3. Loosen off ball valve jam screw and reattach ball valve
cradle onto the relocation plate (included in the manual
bag, refer to Figure 84 for proper geometry and orien-
tation). Re-tighten jam screw and ensure ball valve is
secure.
4. Use appropriate thread sealant and connect the 1/2”
elbow fitting (included in the manual bag). Orientate the
fitting downward.
5. Work the flex line and get the gas connection assembly
into position as shown in Figure 86. Attach the assembly
to the firebox using two (2) 5/16” hex head bolts from
below.
Figure 82: Gas Plate Disconnection
Figure 83: Gas Plate Removal Figure 84: Gas Adapter Connection
Figure 85: 1/2” Elbow Fitting Connection
Figure 86: Gas Connection Re-installation