5-4
EMP-822/EMP-83/EMP-X5/EMP-S5
SEIKO EPSON Revision:A
Error Log Window (Page 2)
While the AS menu is displayed, the Error Log Window can be displayed by pressing the
[Right] button. To go back to the AS menu, press the [Left] button.
• The last 5 error logs are displayed (the latest on top). None is displayed if there’s no error.
• In the case of the above window, the latest error is “Cinema Filter Error” (TOT: 5 hours 36
minutes 27 seconds, LOT: 9 hours 46 minutes 57 seconds, POT: 0 hours 2 minutes 23 sec-
onds, PJ’s status: Lamp ON).
• The 2nd latest error is “Fan Error” (TOT: 5 hours 34 minutes 4 seconds, LOT: 8 hours 35
seconds 34 minutes, POT: 0 hours 0 minutes 1 second, PJ’s status: Warming up).
Item Contents Representation
Error Log
CD Error Code Two alphabets
TOT Total Operation Time h: 5-digit number (00000-65535)
Over 65535: “65535” (Not cleared to “0.”)
m: 2-digit number (00-59)
s: 2-digit number (00-59)
LOT Lamp Operation Time
POT Time after Lamp is ON
ST PJ (Projector)’s status Acquired data of PWR? of the ESC/VP21 command
CD TOT (h
:m:s) LOT (h:m:s) POT (h:m:s) ST
:m:s) LOT (h:m:s) POT (h:m:s) ST
Error
: CF
00005 3627 00009 4657 00000 0223 01
00005 3627 00009 4657 00000 0223 01
Log
: FN
00005 3404 00008 3534 00000 0001 02
00005 3404 00008 3534 00000 0001 02
: LC
00005 0516 00008 4246 00000 1441 01
00005 0516 00008 4246 00000 1441 01
: LF
00004 4221 00007 3451 00000 0000 02
00004 4221 00007 3451 00000 0000 02
: LF
00004 4221 00007 3451 00000 0000 02
00004 4221 00007 3451 00000 0000 02
Error
: TH00 FN01 SE00 LE00 LF02 RA00 RO00 II00
: TH00 FN01 SE00 LE00 LF02 RA00 RO00 II00
Count
: ID00 LC01 EC00 CF01 AI00 RS00 RP00
: ID00 LC01 EC00 CF01 AI00 RS00 RP00
Control
:
1C1D 73717497
Ter ms
Last 5 error logs:
Latest on top
Error Count
Control Data 2
Control Data 1