5.1.2 Initializing (Resetting) the AS Menu Values
The operational procedures and the values of initialization of the AS Menu are shown below.
Item Contents Representation
Error Count
(times)
TH Internal overheat
2-digit number (00-99)
Over 99: “99”
(Not cleared to “0.”)
FN Fan error
SE Thermistor error
LE Lamp burnt out
LF Lighting failure
RA Internal error (RAM)
RO Internal error (ROM)
II Internal error (I2S)
ID Internal error (DR)
LC Lamp cover open
EC
Connection failure to Electrical double
layer capacitor
CF Cinema Filter error
AI Auto IRIS error
RS Sub system ROM error
RP Sub system error (PW error)
Control
Control
data 1
Thermal data of each thermistor
Acquired data of TEMP? of the
ESC/VP21 command
Control
data 2
Voltage of each fan
Acquired data of TEMP? of the
ESC/VP21 command
Type
Clearing the Lamp
Information
Clearing the AS
Information
Clearing the Log
Information
Operation
Press
[Up] and [Source]
for 10 sec. during
displaying Page 1/Page 2.
Press [Down] and [Source]
for 10 sec. during
displaying Page 1/Page 2.
Press
[Right] for more
than 5 sec., then within 3
sec. press
[Select] for 2
sec. during displaying
Page 2.
Item
Total Operation Time No Change Reset to 0H No Change
Lamp Operation Time
(C/H/M/L)
Reset to 0H Reset to 0H No Change
Lamp ON Reset to 1 Reset to 1 No Change
Lamp OFF Reset to 0 Reset to 0 No Change
Lamp Replacement
Add 1 to the
current value
Reset to 0 No Change
Cool Down Complete Reset to 0 Reset to 0 No Change
Error Log No Change No Change
Spacing
(Status of acquiring none)
Error Count No Change No Change Reset to 0
Control No Change No Change No change