Setup & Operation 1. Safety
10 S5 Rev.5
Precautions for use
CAUTION
■
After the brake release unit is disconnected, be sure to
connect the external short
connector. Otherwise, you cannot release the brakes.
Keep the external short connector.
Otherwise you cannot
release the brakes.
If you turn ON the brake release unit while the brake release switch is being
pressed, an unintended arm may move downward.
Before turning ON the brake release unit, make sure that the brake release
switch is not pressed.
If you turn ON the brake release unit without the connector, it may lead to the
short for the male pin used in the connector.
Before turning ON the brake release unit, make sure that the connector is
connected.
When you purchased several
S5 series Manipulators and use the brake release
unit in the manipulator without the connection cable, you need to change the
connection cable inside the manipulator.
To skip this switching work, purchase the cable set for the brake release unit.
ou purchased the manipulator and connection cable together, the cable has
been installed to the manipulator before shipment.
additional external short connector or connection cable, please contact us.