85
Parent topic: Fixing the Ink
Fixing Conditions (Heat Tunnel)
Optimum conditions vary depending on the heat tunnel. Test and check the results in advance to
determine the correct temperature and duration.
Note: The temperature in the tables here refer to the temperature of the fixing surface of the T-shirt, not
the internal temperature of the heat tunnel. If the surface of the T-shirt exceeds 356 °F (180 °C), the T-
shirt and the print surface may change color.
Fixing color ink
Type of heat tunnel Temperature Time
Batch 320 °F (160 °C) 3.5 to 5 minutes
Conveyer 3.5 to 4.5 minutes
Fixing White ink
Type of heat tunnel Temperature Time
Batch 320 °F (160 °C) 5 minutes
Conveyer 4.5 minutes
Parent topic: Fixing the Ink