EasyManua.ls Logo

Ericsson MINI-LINK E - 6.1.5.2 Loops for MINI-LINK E Micro

Ericsson MINI-LINK E
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MINI-LINKEandEMicro
Table 10 SAU terminal alarm list
Alarm Description
Configuration Configuration failure.
Proc. Hardware A hardware fault is detected within the CSS of the unit.
EEPROM Programming of the non-volatile memory in the unit is interrupted.
Service Channel
1, 2
Ser vice channel failure.
User Input Active User Input.
RAC 1, 2 RAC failure.
EAC Communication is lost on the EAC to all other terminals on the EAC.
NCC Ext Communicati on is lost on the NCC to any ter minal on the NCC.
6.
1.4.2
Al
arms for MINI-LINK E Micro
Ta
ble 11 Transmitter alarms
Alarm Description
TX LOS
Transmitting direction, input traffic failure to the MINI-LINK E Micro.
Input E1:X Input traffic failure on a 2 Mbit/s traffic signal in the transmitting direction.
TX FAIL Transmitting direction, internal failure in the MINI-LINK E Micro.
Input E1:X Clock The internal data rate does not correspond with the received data rate.
This will cause a bit slip in the composite bit stream.
Mod Index The modulation index, controlled by far-end, is out of allowed range.
RF Output Level A major degradation of transmitter RF output level. Note: This alarm is
only enabled if the transmitter is on.
Tx Frequency The transmitter frequency loop is unlocked. The fault tur ns off the
transmitter.
100 AE/LZT 110 2012 R8C 2002-03-04

Table of Contents