EasyManua.ls Logo

Ericsson MINI-LINK E - 8.10 DDU Data; 8.11 PSU Data

Ericsson MINI-LINK E
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MINI-LINKEandEMicro
Operation and Maintenance I nterface
Type RS 232C (V.24/V.28)
Format 8 bits, no par ity
Bit rate 1 200 bit/s
Connector type 9-pin D-sub
Note: An IEEE 802.3 10BASE-T interface with RJ-45 connection is provided
by using the ter minal server descr ibed in Section 7.5 on page 124.
User Outputs
Applicable to User 9 12. User 9 12 can be set individually as inputs or
outputs. They can be set for access module summary alar m or remote control.
Ty p e R e l ay
Contact rating DC 60 V DC, 1 A, 30 W
Contact rating AC 42 V AC, 1 A, 60 VA
Alarm state Closed
Connector type 25-pin D-sub, unearthed contacts
User Inputs
Applicable to User 1 8. User 9 12 can be set individually as inputs or outputs.
Type 5 V CMOS, optocoupler
Maximum voltage 15 V
Logical zero < 1.0 V (or < 1.0 k
to earth)
Logical one > 3.5 V ( or > 100 k
to earth)
Resistance to SAU earth 800 k
Maximum DC voltage to SAU
earth 60 V
Connector type 25-pin D-sub
Alar m condition and alarm severity are selectable in MSM.
148
AE/LZT 110 2012 R8C 2002-03-04

Table of Contents