EasyManua.ls Logo

Ericsson MINI-LINK E - 8.6 Interfaces; 8.6.1 MINI-LINK E; Traffic Interfaces

Ericsson MINI-LINK E
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MINI-LINKEandEMicro
Power Consumption for MINI-LINK E with RAU2
Table 35 Maximum terminal power consumption for MINI-LINK E with RAU2
Traffic capacity [Mbit/s]
Terminal type
2x2 4x2 8x2 17x2
Unprotected
32 W 34 W 39 W 44 W
Protected
68 W 72 W 74 W 81 W
With SAU, ETU, fan unit and MXU add 10 W each.
Power Dissipation for MINI-LINK E w ith RAU2
Table 36 M aximum terminal power dissipation for MINI-LINK E with RAU2
Traffic capacity [Mbit/s]
Terminal type
2x2 4x2 8x2 17x2
Unprotected
12 W 14 W 19 W 24 W
Protected
28 W 32 W 34 W 41 W
With SAU, ETU, fan unit and MXU add 10 W each.
8.4.2 MINI-LINK E Micro
MINI-LINK E Micro with DC and Traffic Cables
Input DC Voltage 24 60 V DC, nominal
(20.4 72.0 V DC including tolerance)
Power Consumption (DC) 22 W
141
AE/LZT 110 2012 R8C 2002- 03-04