MINI-LINKEandEMicro
Test Port In
Test Port Out
Traffic In
Traffic Out
Test Port In
Test Port Out
Traffic In
Traffic Out
Analyser
Monitor
BIT
Generator
BER
Detector
Route
3576
Figure 76 Test Port facilities: Monitor and Route
6.1.7 Other Cont rol Functions
Other control functions are:
P-mark
P-mark is a valuable facility during fault location. With P-mar k activated, all
alarm signals are generated and can be read in the normal way, but alarm
notification m essages are inhibited.
TX On/Off
Transmitter can be set on or off.
Switch Mode (for 1+1 configurations only, applicable for MINI-LINK E)
Can be set to auto or manual. In automatic mode (set by default) switching is
controlled by the state of different alarms. See Section 3.9.2.6 on page 58 for
details. In manual mode, the user selects transmitting (1+1 Hot standby only)
and receiving radio, irrespective of alarm status.
Restore
For resetting of the control functions in the terminal to default values.
Reset
Used to reset the processor in a selected unit w ithin the terminal.
107
AE/LZT 110 2012 R8C 2002- 03-04