MINI-LINKEandEMicro
8.5 Cables
For i nfor m ation on product numbers for the cables mentioned in this chapter,
see the MINI-LINK E and E Micro Product Catalog (AE/LZT 110 2011).
8.5.1 MINI-LINK E
8.5.1.1 Radio Cable
The 50
coaxial radio cable is used for connecting the radio unit to the MMU.
DC Resistance
Inne
r/outer conductor loop
<4
Attenuation
Table 37 Attenuation for radio cable
Outer cable
diameter [mm]
Attenuation at 140 MHz
[dB/100 m ]
Attenuation at 350 MHz
[dB/100 m ]
Maximum cable
length [m]
10.3 6.0 9.0 200
16
(1)
3.0 4.7 400
28
(2)
1.5 2.4 700
(1) Sometimes called 1/2"
(2) Sometimes called 7/8"
Mechanical Data
Table 38 Mechanical data for radio cable
Outer cable diameter [mm] Weight [kg/100 m]
Minimum bending radius [mm]
10.3 13 100
16
(1)
22 125
28
(2)
49 25
0
(1) Sometimes called 1/2"
(2) Sometimes called 7/8"
143AE/LZT 110 2012 R8C 2002- 03-04