Card Descriptions
Table 85 Facility LEDs on Controller Cards
Label Activity Color Description
On Green The link is present and active.
Blinking Green The link is transmitting or receiving frames.
LINK/ACTIVITY
LINK/ACT
Off None The link has no active frame.
On Green The link is operating at 1 Gbps (XCRP4 only)
On Yellow The link is operating at 100 Mbps.
SPEED
Off None The link is operating at 10 Mbps.
Table 86 Synchronization and External Timing LEDs on Controller Cards
Label Activity Color Description
On Green At least one of the selected synchronization references is in good
condition and is providing reference.
SYNC
Off None The selected synchronization reference is external, and all external
references have failed. The timing is being internally generated.
On Yellow The primary input signal from the external equipment has been
configured (provisioned), but is not present.
EXTERNAL TIMING
LOS PRI
Off None The primary input signal has not yet been configured or has been
configured and is present.
On Yellow The secondary input signal from the external equipment has been
configured but is not present.
EXTERNAL TIMING
LOS SEC
Off None The secondary input signal has not yet been configured or has been
configured and is present.
6.1.2 Supporting Information
The following sections provide information about functional components of
the XCRP4 Controller card.
6.1.2.1 Processors
The XCRP4 Controller card has four processors: one processor runs the
low-level software and the other three processors run the BRAS and routing
software. Support for more than one processor to run the BRAS and routing
software depends on the release of the SmartEdge OS.
6.1.2.2 Main Memory
Synchronous Dynamic Random Access Memory (SDRAM) is used by the
SmartEdge OS shared databases that are accessed by the line cards. In a
chassis with two controller cards, both cards must have the same memory
configuration
111
27/153 30-CRA 119 1170/1 Uen A | 2010-04-09