Hardware Control and Troubleshooting
Table 35 Port Types
Port Type Description
atm
ATM OC-3 or ATM OC-12 port
pos
OC-192c/STM-64c, POS OC-3c/STM-1c, POS OC-12c/STM-4c, and POS OC-48c/STM-16c
ethernet
Ethernet or Gigabit Ethernet port (any version)
3.5 Output Fields for the show chassis Command
Table 36 Output Fields for the show chassis Command
Field Description
Current platform is Chassis type: SE600 chassis.
Slot slot—Slot number for this unit.
Configured type Slot is configured for one of the following card types:
traffic-card-type—Line card is configured.
(1)
xcrp—Controller card of any type or controller carrier card is configured.
ase—Advanced Services Engine.
sse—SmartEdge Storage Engine.
none—Slot is not preconfigured.
Installed type Slot has card installed:
carrier—I/O carrier card; always reported for slot 2.
traffic-card-type—Line card is installed.
xcrp—Controller card of any type or controller carrier card is installed.
ase—Advanced Services Engine.
sse—SmartEdge Storage Engine.
none—Slot is empty.
unknown—Controller card is installed but not initialized.