Site Preparation
Table 10 Tools Needed for SmartEdge 600 Hardware Installation
Tool Purpose
#1 Phillips screwdriver Remove and install the fan tray and cable tray; remove and install the cards. The
screwdriver needs a 0.1875-inch barrel that is 5 to 6 inches long to install and
remove the cable tray.
#2 or #3 Phillips screwdriver
(1)
Attach the mounting brackets to the chassis and air ramp. Install the chassis and air
ramp in the rack.
7/16-inch torque wrench Connect the chassis ground cables.
Cable crimping tool
(2)
Secure barrel or open lugs to the DC power and chassis ground cables.
(3)
(1) Depending on the screws that you use to install the chassis in a rack, a #3 Phillips screwdriver might be more
appropriate than the #2 screwdriver.
(2) The OUR840 manufactured by Burndy Tooling (recommended) or equivalent.
(3) When barrel lugs are not provided, other options are available to secure the conductors.
1.14 Management Access Cables
A management access cable connects a console terminal, management
workstation, or modem to a port on a controller card or the chassis.
Table 11 Cable Specifications for Management Access Cables
Name Description System Connectors Cable Connector Maximum Length
(1)
Craft console cable RS-232 DB-9 female DB-9 male 35.0ft - 10.7m
Ethernet crossover cable Category 5 shielded twisted-pair RJ-45 female RJ-45 male 328.1ft - 100.0m
Ethernet straight cable Category 5 shielded twisted-pair RJ-45 female RJ-45 male 328.1ft - 100.0
(1) The maximum cable length for RS-232 cables is for any baud rate.
1.14.1 Craft Console Cable
This cable connects a local Craft console to the Craft 2 port on a controller
card. The cable is constructed as a straight-through connection between a
DB-9 male connector at the system end and a DB-9 female connector at the
computer terminal end.
Table 12 Craft Console Cable Pin Assignments
Signal Name
(1)
Signal Function Notes
DCD (input) Received Line Signal Detector Not used
TXD (output) Transmitted Data SmartEdge 600 output
RXD (input) Received Data SmartEdge 600 input
DSR (input) DCE Ready Not used
–
Signal Ground
–
DTR (output) DTE Ready Not used
CTS (input) Clear to Send Not used
1327/153 30-CRA 119 1170/1 Uen A | 2010-04-09