SmartEdge 600 Router Hardware Guide
13. Power on the chassis by connecting the AC power cords to separate 220
VAC building outlets, each of which must be for a circuit rated at 20A with a
20A circuit breaker.
Note: The AC power cords ship with North American plugs installed. If
you are connecting to another type of service, simply remove the
plugs and replace them with the appropriate plugs.
14. Check the status LEDs located on the alarm card at the front of the chassis
and the AC input power and DC output power LEDs on the front of each
installed power module.
If you encounter problems installing the AC power shelf, contact your local
technical support representative.
2.6 Card Slots
Figure 11 SmartEdge 600 Card Slots
Table 25 Slot Assignments for SmartEdge 600 Cards
Card Slots Available
Controller
7, 8
ATM OC-12c/STM-4c
ATM OC-3c/STM-1c (any version)
1to6
10/100 Ethernet
Fast Ethernet–Gigabit Ethernet
1to6
20-port Gigabit Ethernet 1020
(1)
Transceiver-based Gigabit Ethernet (any other version)
1to5
1to6
OC-192c/STM-64c (any XFP version)
1to6