SmartEdge 600 Router Hardware Guide
Table 105 1-Port OC-192c/STM-64c Card Specifications
Specification SR-1 IR-2 LR-2
Transceiver type XFP XFP XFP
Compliance ITU G.693 GR-253 SR-1
GR-1377-CORE
GR-253 IR-2 GR-1377-CO
RE
ITU G.959.1 P1L1-2D2,
GR-253 LR-2b
GR-1377-CORE
(1) The port has separate connectors for the transmit (Tx) and receive (Rx) circuits.
(2) The speed of the Ethernet XFPs is 10.3125 Gbps and OC-192 XFP is 9.95 Gbps.
6.8.1 Status LEDs
Figure 42 Status LEDs on 1-Port OC-192c/STM-64c Card
Table 106 Equipment LEDs on 1-Port OC-192c/STM-64c Card
Label Activity Color Description
On Red A failure exists on the card.
(1)
FAIL
Off None No failure exists on the card.
On Green This card is in service.ACTIVE
Off None This card is either on standby (the STDBY LED is on) or has failed (the FAIL
LED is on).
On Yellow At least one of the ports on this card has been configured as a protection port.
(2)
STDBY
Off None None of the ports on this card has been configured as a protection port.
(1) A failure can be total, partial, or forced. Failure on any part of the card, including failure of any of its ports, results in
the FAIL LED being on.
(2) Protection for cards and ports depends on the release of the SmartEdge OS.
130 27/153 30-CRA 119 1170/1 Uen A | 2010-04-09