Table 22 10/100 Ethernet Straight Cable Pin Assignments
Signal Name Notes
Termination network
Tx (–)
Termination network
Termination network
1.18.3 Fast Ethernet Breakout Cable Pin Assignments
Table 23 Fast Ethernet Breakout Cable Pin Assignments
Port MRJ21 Pins RJ-45 Pins Colors
1 121314 1236
White/Blue Blue/White White/Orange Orange/White
2 341516 1236
White/Green Green/White White/Brown Brown/White
3 25263728 1236
White/Gray Gray/White Red/Blue Blue/Red
4 27283940 1236
Red/Orange Orange/Red Red/Green Green/Red
5
561718 1236
Red/Brown Brown/Red Red/Gray Gray/Red
6 781920 1236
Black/Blue Blue/Black Black/Orange Orange/Black
7
29 30 41 42 1 2 3 6
Black/Green Green/Black Black/Brown Brown/Black
8 31324344 1236
Black/Gray Gray/Black Yellow/Blue Blue/Yellow
9 9 10 21 22 1 2 3 6
Yellow/Orange Orange/Yellow Yellow/Green Green/Yellow
10 11 12 23 24 1 2 3 6
Yellow/Brown Brown/Yellow Yellow/Gray Gray/Yellow
11 33 34 45 46 1 2 3 6
Violet/Blue2 Blue/Violet Violet/Orange Orange/Violet
12 35 36 47 48 1 2 3 6
Violet/Green2 Green/Violet Violet/Brown Brown/Violet