SmartEdge 600 Router Hardware Guide
Table 29 Components Tested by POD
Component Component Argument Values
Fan tray
fan tray
Line card card n (slot number 1 to 6)
The detail keyword allows you to determine which test the component has
failed.
In general, if a component fails to pass its power-on diagnostic tests, you need
to replace it or make arrangements for its replacement. Contact your technical
support representative for more information about the results of a failed test.
Power-on diagnostics are enabled by default in the operating system. If they
have been disabled, you can enable them with the diag pod command in
global configuration mode.