Hardware Control and Troubleshooting
Table 31 CLI Commands for Hardware Configuration and Control
Task or Information Needed CLI Command Comments
Restart the system (reload the controller)
reload
The reload command does not reset
the hardware.
Restart a line card (reload its software)
reload card slot
Reload the SSE disk
reload disk slot_number_disk_num
Restart (enable) a port
port port-typeslot/port
no shutdown
Hardware data—Version, slot number, port number, physical layer interface, speed, mode, counters
Summary information
show chassis
show hardware
show port
Detailed information
show hardware fantraydetail
show hardware card slot slot detail
show port detailslot/port
Configuration data—Slots, ports
Summary information for each slot
show chassis
Current configuration information for all SSE
groups
show configuration sse
Summary information for each SSE hard disk
drive
show disk sse slot
Summary information for all SSE hard disk drive
counters
show disk sse counters slot disk_num
Summary information for each installed line card
show port
Summary information for each installed
transceiver
show port transceiver
Configuration for a specific port
show portslot/port detail
Use the all keyword to display data
for all ports that are not installed.
Summary information for each installed SSE
card
show sse { group [ group_name ] |
partition [ partition_name ] }
Summary information for all SSE counters
show sse counters
Summary information for all SSE group and
partition alarms
show system alarm sse{ group
[ group_id ] | partition [
partition_id ] }
Shut down an SSE HD shutdown disk disk ID
Summary information for all transceiver alarms
system alarm transceiver
When reporting alarms and warnings,
the SFP transceivers must be
compliant to SFF-8472 and the XFP
transceivers must be compliant to
INF-8077i.
(1) Because the SmartEdge OS software synchronizes all write operations to the file system, you can power down
the system without issuing the shutdown command.
5127/153 30-CRA 119 1170/1 Uen A | 2010-04-09