EasyManua.ls Logo

Ericsson SmartEdge 600 - Page 71

Ericsson SmartEdge 600
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Control and Troubleshooting
Table 46 Output Fields for the show port Command with the detail Keyword
Field Value/Description
Clock Source
(1)
State of source of the transmit clock:
global-reference—system clock on the active controller card.
(2)
local—local clock located on the line card (onboard clock).
(3)
loop—receive clock derived from the incoming signl on the port.
card-reference—clock source that has been specified for the line cards.
Crc Configured value of the cyclic redundancy check for a SONET/SDH port (16 or 32).
Dampening Count n—Number of instances this link-dampened port went down and came up within the limits set by
the
link-dampening command. This count is reset only when the port is removed from the
configuration with the no form of the port command (in ATM OC or port configuration mode).
Description Configured description.
Diag Monitor No—SFP cannot monitor its faults nor report power readings
Yes—SFP can monitor its faults and report power readings
DSU Bandwidth nn.nn Mbps—Bandwidth of configured data service unit (DSU).
DSU Mode digital-link—Configured vendor of DSU.
DSU Scramble DSU scramble condition (on or off).
Duplex Mode full—Port condition, Ethernet or Gigabit Ethernet (any version).
half—Port condition,10/100 Ethernet only.
Encapsulation The encapsulation for this port:
802.1q
atm
cisco-hdlc
ethernet
frame-relay
ppp
FEAC code received Far end alarm condition (of the remote system):
Service affecting (SA) equipment failed.
Nonservice affecting (NSA) equipment failed.
Common equipment failed.
N/A or NONE—No alarm condition received.
Flow control Condition of flow control for Gigabit Ethernet port, any version, (on or off).
Framing Configured framing for the port:
c-bit
g751
m23
ESF
•SF
sdh (an option of ATM OC, POS, and WAN-PHY ports)
sonet (an option of ATM OC, POS, and WAN-PHY ports)
6527/153 30-CRA 119 1170/1 Uen A | 2010-04-09

Table of Contents

Related product manuals