ESAB CUTMASTER 80
Manual0-5396 INTRODUCTION
2-3
2.05 InputWiringSpecications
ESAB Cutmaster
®
80 Power Supply Input Cable Wiring Requirements
Inputvoltage Freq Power Input Suggested Sizes
Volts Hz kVA I max I eff Fuse (amps)
Flexible Cord
(AWG)
3 Phase
400 50/60 11.8 17 11 20 12
Line Voltages with Suggested Circuit Protection and Wire Sizes
BasedonNationalElectricCodeandCanadianElectricCode
NOTE!
RefertoLocalandNationalCodesorlocalauthorityhavingjurisdictionforproperwiring
requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.